Reliable, enclosed-arc switching for transformer protection

Our versatile interrupters perform in any orientation and can be configured with or without an integral disconnect.

The Southern States' horizontal interrupter circuit switchers are engineered for transformer protection on systems with fault currents up to 40 kA — all while eliminating open air arcs by performing make and break operations entirely in SF₆. These interrupters are available with or without an integral vertical break switch and can be installed in horizontal, upright, or vertical configurations.

Each model offers exceptional mounting flexibility: attach to existing substation structures, custom supports, or Southern States frames. The CSH(2)-B variant is ideal for mobile substation use, with composite housings that allow the unit to be shipped fully pressurized — no special crating or shielding required.

Key Benefits:

  1. All switching in SF₆ — no open air arcs
  2. Available with or without vertical break disconnect
  3. Visual dielectric indication for added safety
  4. Pressurized transport with composite or shielded porcelain housing
  5. Accommodates a wide range of mounting heights, orientations, and phase spacings
  6. Ideal for retrofits — upgrade the interrupting capability of existing switchers, fuses, or disconnects using current structures
  7. Backed by Southern States' 24/7 after-sales support and long-life engineering

Choose voltage rating:

Blade BIL Ratings (for CSH-B)

Ratings CategoryRatings
Max Voltage38 kV48.3 kV72.5 kV123 kV145 kV170 kV
Blade BIL200 kV250 kV350 kV550 kV650 kV750 kV

550 kV BIL Interrupter Ratings*

Type
Temp Range1
≤ 72.5 kV123 kV
PBF 100s-30° C to +50° C20 kA
-40° C to +50° C25 kA
-50° C to +40° C
15 kA 5
12 kA 5
TLF-40° C to +50° C4 kA
2.9 kA 2
-50° C to +40° C
2.5 kA 5
1.7 kA 5
  1. Ratings shown are for 1200A. For 1600A, top temp is +40°C.
  2. Nameplate will include note “TLF = 4 kA @ 7.6 kV/µs TRV”
  3. Ratings do not apply to 2000A
  4. Ratings apply to both porcelain and composite interrupter housings
  5. SF6 / N2 Gas Mixture
  6. All ratings are suitable for ungrounded systems (1.5 kpp)

750 kV BIL Interrupter Ratings*

Model
Temp Range1
≤ 72.5 kV123 kV145 kV***
170 kV 6
PBF 100s-40° C to +50° C25 kA
20 kA 3
-50° C to +40° C
15 kA 6
12 kA 6
TLF**-40° C to +50° C4 kA
2.9 kA 2
2.3 kA 2
2.7 kA 2
-50° C to +40° C
2.5 kA 4
1.7 kA 4
1.4 kA 5
1.6 kA 6
  1. Ratings shown are for 1200A. For 1600A, top temp is +40°C.
  2. Nameplate will include note “TLF = 4 kA @ 7.6 kV/µs TRV”
  3. Ratings do not apply to 2000A.
  4. Ratings apply to both porcelain and composite interrupter housings
  5. 170 kV ratings are for grounded systems (1.3kpp)
  6. SF6 / N2 Gas Mixture

Blade BIL Ratings (for CSH2-B)

Ratings CategoryRatings
Max Voltage 38 kV48.3 kV72.5 kV123 kV145 kV
Blade BIL200 kV250 kV300 kV550 kV650 kV

650 kV Interrupter Ratings*

Type
Temp Range1
≤ 72.5 kV123 kV
145 kV 2
Interrupter Housing
PBF 100s-30° C to +50° C40 kAComposite
-40° C to +50° C31.5 kA Composite
TLF**-40° C to +50° C4 kAComposite
  1. Ratings shown are for 1200A. For 1600A, top temperature is +40°C.
  2. The 145 kV rating is for grounded systems (1.3kpp)
  3. The CSH2 is currently not offered at temperatures below -40°C.
Ratings CategoryRatings
Maximum kV Rating245 kV *
Interrupter/Blade BIL (kV)900 kV
Continuous Current1200 A & 1600 A for all kV ratings **
Primary Fault Interrupting 20 kA (12 kA for -50° C)
Transformer Limited Fault4 kA
Interrupting Time6 Cycles
Power Frequency 60 Hz
Short-Time Withstand40 kA / 3 sec
Peak Withstand108 kA
Short-Circuit Making40 kA
Ambient Temperature Range
-30° C to +50° C (Standard)
(-50º C to +50º C Optional)
*
The 245 kV rating is suitable for Grounded Systems
**
Consult factory for higher current ratings